技術文章
ASTM G154-16
閱讀:882 發布時間:2019-8-22ASTM G154-16
本頁面標準信息均來源于網絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結果的準確性、節省您的時間,如需ASTM G154-16標準詳細信息或ASTM G154-16具體測試方法,請與我們技術人員聯系或給我們留言,我們將為您提供相關的技術支持。
ASTM G154-16是個關于暴露在陽光日曬、持續潮濕、加熱而導致產品性能老化的測試方法,現行標準修訂于2016年。
1. Scope
1.1 This practice is limited to the basic principles for operating a fluorescent V lamp and water apparatus; on its own, it does not deliver a specific result.
1.2 It is intended to be used in conjunction with a practice or method that defines specific exposure conditions for an application along with a means to evaluate changes in material properties. This practice is intended to reproduce the weathering effects that occur when materials are exposed to sunlight (either direct or through window glass) and moisture as rain or dew in actual usage. This practice is limited to the procedures for obtaining, measuring, and controlling conditions of exposure.
Note 1: Practice G151 describes general procedures to be used when exposing nonmetallic materials in accelerated test devices that use laboratory light sources.
Note 2: A number of exposure procedures are listed in an appendix; however, this practice does not specify the exposure conditions best suited for the material to be tested.
1.3 Test specimens are exposed to fluorescent V light under controlled environmental conditions. Different types of fluorescent V lamp sources are described.
Note 3: In this standard, the terms V light and V radiation are used interchangeably.
1.4 Specimen preparation and evaluation of the results are covered in ASTM methods or specifications for specific materials. General guidance is given in Practice G151 and ISO 4892-1.
Note 4: General information about methods for determining the change in properties after exposure and reporting these results is described in ISO 4582 and Practice D5870.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.7 This standard is technically similar to ISO 4892-3 and ISO 16474-3.
2. Referenced Documents
ASTM Standards
D5870 Practice for Calculating Property Retention Index of Plastics
D6631 Guide for Committee D01 for Conducting an Interlaboratory Study for the Purpose of Determining the Precision of a Test Method
G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials
G151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that se Laboratory Light Sources
G177 Tables for Reference Solar ltraviolet Spectral Distributions: Hemispherical on 37 Tilted Surface
ISO Standards
ISO 16474-3 Paints and VarnishesMethods of Exposure to Laboratory Light SourcesPart 3: Fluorescent V Lamps
ISO4582 PlasticsDetermination of the Changes of Colour and Variations in Properties After Exposure to Daylight nder Glass, Natural Weathering or Artificial Light
ISO4892-1
kingjo-V老化試驗箱用于ASTM G154 cycle-4的測試方法