1 Scope

This test method shall be used to determine the effects of weathering using a xenon-arc lamp source(artificial sunlight) to simulate extreme environmentalconditions encountered inside a vehicle due to sunlight, heat and humidity. This method shall be used toevaluate the colorfastness, as well as being the artificial weathering method to evaluate degradation.

Note:Nothing in this test method supersedes applicable laws and regulations unless a specific exemption has been obtained.

Note:In the event of a conflict between the English and the domestic language, the English languageshall take precedence.

2 References

Note: Only the latest approved standards are applicable unless otherwise specified.

2.1 Normative.

ISO 105-A02

2.2 GM.

GMW6992

2.3Additional.

Equipment Manufacturer's Operating Manuals

3Test Equipment

3.1 Xenon-Arc Weathering Device. The weathering device shall consist of a climatic chamber madefrom corrosion resistant material, which contains thelight source (xenon-arc lamp that is either air-cooledor water-cooled), the filter system and the frameholder for the test specimens. The apparatus mustbe equipped so that it can meet the following parameters and controls.To insure repeatability of tests,the apparatus must be maintained and calibrated tomanufacturer's specification.

3.1.1 Filter System. Fit the xenon-arc burner withthe appropriate optical filters to provide a spectralpower distribution (SPD) that falls within the range indicated in Table 1 and similar to Figure 1. Examplesof filter systems, that will provide this light spectrumdistribution for a few machines, are listed in the Appendix.

3.1.2Irradiance Measuring Device at a location representative of the test specimen location measuringirradiance at one of the following bandwidths.

· W/m2/nm at 420 nm (narrow bandwidth measurement)

· W/m2 at 300 to 400 nm (wide bandwidth measurement)

3.1.3 Black Standard Thermometer (BST). TheBST is an insulated temperature measuring deviceconsisting of a metal panel, having a matte blackcoating which absorbs all wavelengths uniformly, witha thermal sensitive element firmly attached to thecenter of the surface opposite the radiant source.The BST shall measure (70±5) x (40±5) mm andhave a thickness of (0.5±0.1) mm and be fixed to aplastic plate so that it is thermally insulated. The BSTis used to control an artificial weathering device andto provide an estimate of the maximum temperatureof samples exposed to a radiant energy source.

3.1.4 Chamber Temperature (CT) Probe. The CTor the temperature of the air in the test chamber shallbe measured and controlled.

3.1.5Chamber Relative Humidity (RH) MeasuringDevice. The RH of the test chamber air shall be measured and controlled.

3.1.6 Purified Water. Water for humidification andlamp cooling must be purified so that it contains nomore than 0.2 ppm of silica and has no more than 1.0ppm total dissolved solids.

3.2Gray Scale for assessing color change complyingwith the requirements of ISO 105-A02.

3.3 Color Machine (if applicable) - Spectrophotometer capable of CIELAB measurements, with a 10 degree standard observer, a D65 standard illuminantand an orifice size greater or equal to 20 mm. Theacceptable machine geometries are: 45 degree/normal (45/0), normal/45 degree (0/45), diffused/normal(d/0), or normal/diffused (0/d).If a diffused geometry instrument is used, the specular component of reflectance shall be included in the measurement. Theangle between the sample normal and the illuminating beam in 0/d geometry, and the angle between thesample normal and the viewing beam in d/0 geometry, shall not exceed 10 degrees.

3.4 Suitable stamping dies, shears or cutting equipment for preparation of test specimens.

4 Test Material

4.1White Cardboard. Back the textile test specimens with white opaque cardboard or card stock withsufficient weight to prevent warping. The materialshould have a low sulfur content and be free from fluorescent brightening agents.

4.2 Non-woven fleece (Atlas part# 56077020) orequivalent shall be used between textile test specimens and the white cardboard, if the test specimenis less than 8 mm thick.

4.3 Standard Reference Material (SRM). Blue Woolor Polystryene reference standards are to be used indetermining whether the xenon-arc apparatus is operating within the desired range.

5 Test Method

5.1 Summary of Test Method. Test specimens areexposed in a xenon-arc weathering device to artificialweathering conditions, which simulate extreme environmental conditions, encountered inside a vehicledue to sunlight, heat and humidity. Test specimensare then evaluated for colorfastness (fade) or othermodes of degradation.

5.2Test Sample Preparation.

5.2.1For colorfastness, cut at least one test specimen of a size that fits the test specimen holderframes for the equipment being used. Back each testspecimen with the non-woven fleece, if required, andthe white cardboard then insert and secure into theholder.

5.2.1.1The test specimen shall include all variationsof color and pattern or multiple test specimens mustbe taken so that all variations of color and pattern areincluded in the test.

5.2.1.2When testing narrow textile materials or smallparts, use as large a test specimen as possible andback it with white cardboard that fits the test specimenholder.

5.2.2For degradation evaluations, cut the numberand size of test specimens required for the degradation test. Back the exposure area with the white cardboard, then fold and secure any excess material behind the white cardboard.

5.3Test Procedure.

5.3.1Mount the test specimen holders in the weathering device with the face side of the test specimen nocloser to the lamp than the front side of the specimenholder.

5.3.2 Fill all unused places with specimen holdersfilled with dummy textile blanks to maintain desiredairflow. Blanks should be changed when noticeablephysical distortion and/or degradation occur.

5.3.3Expose test specimens in the xenon-arc weathering device, meeting the following parameters, for thespecified exposure cycle and duration defined in therelevant material specification.

5.3.3.1Exposure Cycles.

5.3.3.1.1 Light/Dark Exposure Cycle (Cycle A).

This cycle alternates between light and dark periods.The light periods will last 3.8h± 6minutes and thedark periods will last 1h ± 6minutes. Initiate eachnew test before the start of a light period.

5.3.3.1.2Light Only Exposure Cycle (Cycle B).This alternate cycle could be used for colorfastnessevaluations only, of material proven to show equalresults with the light/dark cycle above. For Textiles,this is 100 % polyester fabrics only. This cycle willonly have the light period and eliminate the darkperiod. All other parameters and exposure level willremain the same as the light/dark cycle.

5.3.3.2 Irradiance Level.Irradiance measured at alocation representative of the test specimen locationmust meet one of the following equivalent levels.

· (2.2 ± 0.02) W/m2/nm measured at 420 nm (narrowbandwidth measurement)

· (95 ± 2) W/m2/nm measured at 300 to 400 nm(wide bandwidth measurement)

5.3.3.3 Black Standard Thermometer (BST) Temperature. The BST temperature shall be maintainedat (105 ± 3) ℃ for the light period.

5.3.3.4 Chamber Temperature (CT). The CT or thetemperature of the air in the test chamber shall bemeasured and controlled at (65± 2) ℃ for the lightperiod and at (38± 2) ℃ for the dark period. Temperature equilibrium shall be reached within 20 minutes.

5.3.3.5 Chamber Relative Humidity (RH). The RHof the test chamber air shall be measured and controlled at (25± 5) % RH for the light period and at(95 ± 5) % RH for the dark period.

5.3.4Once exposure has been initiated, equipmentoperation should not be interrupted more than oncedaily. Additional interruptions, e.g., opening thechamber door during the course of daily operation,may cause variation in test results.

Note:Care should be taken to avoid mixing potentially incompatible materials in the samemachineload.

5.3.5Take care to avoid condensation on the lampfilter system which can alter its light output. Referto manufacturer's operating manual on tips to avoidcondensation on lamps.

6Evaluation and Rating

6.1Visual assessment for colorfastness to be madeby a person with a trained eye, use the following ratingscale. Compare the test specimen to a control sampleand the gray scale, under standard lighting defined inGMW6992. All comparisons shall be made with likesized evaluation areas.

10 = No change. No hue or pattern change. No valuechange with a gray scale reading of 5.

8 = Slight Change. No hue or pattern change. Slightvalue change with a gray scale reading of 4 or better.

6 = Noticeable Change.Slight hue and/or patternchange.Noticeable valuechangewith a gray scale reading of 3 or better.

4 = Objectionable Change. Noticeable hue and/orpattern change. Excessive value change with a grayscale reading of 2 or better.

2 = Severe Change. Excessive hue and/or pattern change. Severe value change with a gray scale reading of 1 or better.

6.2Perform color and gloss measurements, if applicable. Calculate the differences between the unexposed control sample or the start of test values of theunexposed sample and the exposed test specimen.

6.3 Degradation evaluations to be completed and reported according to the methods defined in the relevant material specification.

7 Report

7.1 Report the color change rating from visual assessment at each required exposure level. Note anyappearance or degradation changes seen that are notincluded on the color change rating scale.

7.2 If required, report the color machine measurements for color change using the CIELAB measurements for DE, DL, DC, DH, Da, Db at each requiredexposure level.

7.3Note the exposure cycle (see 5.3.3.1) used if notdefined in the relevant material specification.

7.4Provide Standard Reference Material (SRM) datafor the days the test specimen was being tested.

7.5Deviations from this Test Method. Deviationsfrom the conditions of this test method shall have beenagreed upon between supplier and vehicle manufacturer. All deviations shall be specified on componentdrawings, material specifications, etc. and shall be indicated on test certificates, reports, etc.

8Safety

This method may involve hazardous materials, operations and equipment. This method does not proposeto address all the safety problems associated with itsuse. It is the responsibility of the user of this methodto establish appropriate safety and health practicesand determine the applicability of regulatory limitations prior to use.

9 Coding System

This test method shall be referenced in other documents, drawings, VTS, CTS, etc. as follows:

Test to: GMW3414-A

Where:

GMW = Validation Area (GMWorldwide)

3414 = Continuous Number

A = Exposure Cycle (see 5.3.3.1)

10 Release and Revisions

10.1Release. This specification was first approvedin May 2001 and published in April 2002.

This test method was developed by the WW FabricSpecification Team to create a common methodfor evaluating Artificial Weathering. The currentmethods used are SAE J1885 (NA, GMB, Holden);GME60292 (ITDC); ISC-C93-001 (Isuzu Motors);STD3159 (Saab Automotive)

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~

對比框

產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

掃一掃訪問手機商鋪
189-2580-2250
在線留言
主站蜘蛛池模板: 99久久婷婷国产综合精品| 亚洲av无一区二区三区久久久| 日韩精品无码免费一区二区三区 | 亚洲天堂网站| 久久国产精品久久精品| 久久久久久久精品成人热| 91精品国产导航| 一二三四日本无码影视| 911精品国产91久久久久| 麻豆传传媒久久久爱| 91精品视频免费在线观看| 在线观看免费a∨网站| 国产午夜精品一区二区三区| 2024国产综合在线| 精品无码一区二区三区视频在 | 亚洲国产精品精华| 国产香蕉一区二区在线网站| 成人国产精品| 精品日韩欧美| 无码精品一二三四区A片| 凹凸精品熟女在线观看| 精东传媒vs天美传媒在线| 无码欧美毛片一区二区三| 欧美激情x性bbbb| 色综合天天娱乐综合网| 国产精品人妻在线观看| 成人区亚洲区无码区在线点播| 精品熟女一区二区| 久久免费看视频| 亚洲av无码成人精品国产白浆| 国产粉嫩泬一区二区三区| 视频一区在线免费观看| 久久久久亚洲精品无码蜜桃| 91国偷自产一区二区三区蜜臀| 狼友视频国产精品首页| 激情综合久久| 一本道香蕉在线资源| 欧美午夜精品久久久| 精品动漫区一区二在线观看| 亚洲中文字幕精品久久久久久| 国产精品成人av片免费看|