德國(guó)德爾格Drager Pac3500測(cè)量準(zhǔn)確,操作簡(jiǎn)單,是理想的個(gè)人防護(hù)氣體檢測(cè)報(bào)警儀。此儀器可以快速連續(xù)檢測(cè)環(huán)境空氣中的一氧化碳,硫化氫或氧氣的濃度并及時(shí)報(bào)警,使用壽命2年,專為工業(yè)安全應(yīng)用設(shè)計(jì)。
(現(xiàn)貨)技術(shù)參數(shù):
量程 | CO: 0-500 ppm |
H2S: 0-100 ppm | |
O2: 0-25 % by volume | |
報(bào)警點(diǎn) | CO: Alarm 1: 35 ppm, Alarm 2: 50 ppm |
H2S: Alarm 1: 10 ppm, Alarm 2: 20 ppm | |
O2: Alarm 1: 19.5 Vol %, Alarm 2: 23.5 Vol % | |
顯示 | LCD 多語(yǔ)言顯示, 氣體種類等 |
使用時(shí)間長(zhǎng)達(dá) | 2 年 |
使用環(huán)境溫度 | -20 to 120°F |
濕度 | 10 to 90% rH |
防護(hù)等級(jí) | IP 65 |
電池壽命 | CO & H2S: > 2 年 |
O2: > 12 個(gè)月 | |
認(rèn)證 | UL: Class I, Div 1, Group A, B, C, D, E, F, G, T4 |
cUL: Class I, II, Div 1, Group A, B, C, D, E, F, G, T4 | |
ATEX: I/II 1/2 G EEx ia I/IIC, T4 | |
報(bào)警 | 可視, 360° 光亮LEDs 同時(shí)頂部底部, 聲光, multi-tone >90 dB at 1 ft, 震動(dòng) |
尺寸 | 2.5" x 3.3" x 0.8" |
重量 | 約120克 |
功能測(cè)試快速可靠
功能測(cè)試可以檢查儀器是否工作正常。絕大多數(shù)國(guó)家規(guī)范要求用戶利用已知濃度氣體對(duì)儀器進(jìn)行常規(guī)測(cè)試。功能測(cè)試可以檢查儀器是否正常工作。德爾格Pac 3500滿足不同的應(yīng)用配置了可調(diào)節(jié)功能測(cè)試和標(biāo)定間隔,到功能測(cè)試和標(biāo)定要求日期屏幕上會(huì)自動(dòng)顯示警告。如若忽略警告,儀器可自動(dòng)顯示“出現(xiàn)故障”錯(cuò)誤信息。用戶也可以選擇對(duì)標(biāo)定間隔過期設(shè)置此錯(cuò)誤信息提示。德爾格Pac 3500可以與德爾格功能測(cè)試儀配套使用,每次僅8到15秒即可快速簡(jiǎn)單地完成測(cè)試。此經(jīng)濟(jì)型設(shè)備無須電源,可任何地點(diǎn)檢查儀器和傳感器。每次成功的測(cè)試都自動(dòng)記錄在數(shù)據(jù)存儲(chǔ)器中同時(shí)失敗的測(cè)試會(huì)提示儀器“出現(xiàn)故障”。還可選配便攜式打印機(jī)和打印文本結(jié)果。開機(jī)后可以簡(jiǎn)單進(jìn)行新鮮空氣標(biāo)定。所有其它標(biāo)定菜單選項(xiàng)均有密碼保護(hù)。
QUICK AND RELIABLE BUMP TESTING
Bump or function tests are necessary to check if the instruments are functioning correctly. Most national regulations require users to test equipment against a known gas concentration on a regular basis. Featuring adjustable bump test and calibration intervals, the Dräger Pac 3500 alerts the user when bump tests or calibration are required. If this warning is ignored or a test is unsuccessful, the instrument automatically displays an “out of order” error message. Performed together with the Dräger Bump Test Station, a typical bump test takes between 8 and 15 seconds and requires no additional power so that the test can be performed on site. Each test result is automatically stored in the event logger and, should hard copies be required, an optional printer can be used. If necessary, a fresh air calibration can be carried out during the start-up sequence. All other calibration options are only accessible via a password-protected menu.
Pac 5500 CO (EU) 0 to 500 ppm
Pac 5500 H2S (EU) 0 to 100 ppm
Pac 5500 O2 (EU) 0 to 25 Vol.%